banner_about
UPS  48V2000AH

UPS 48V2000AH

The actual system components will be set by the final delivery.

This battery system requires the specific Li-ion battery charger. The customer needs to procure separately

It is required to install and operate the system in a indoor environment with temperature about 30~35℃

This battery system requires the specific Li-ion battery charger. The customer needs to procure separately

I WANT IT
Inquiry ×
Company:*
Qty:*
Address:*
Shipping Method:*
Demand Time:*
Message:*
Verification Code:*
PRODUCT DETAILS
Production Specification
NoNameModel/SpecUnitQty.Note
EP-48V2000AH UPS System includes the folllowing
148V100AH Li-Ion Battery Pack48V100Ah set 20
2Battery  Shelf 48V-2000Ahset 2 Can disassemble and reassemble
3Copper Electrode Bars 48V-2000Ahset 2
Note: 1.The actual system components will be set by the final delivery.
2.This battery system requires the specific Li-ion battery charger. The customer needs to procure separately


 UPS System Specification
NOItemParameters
1 Battery Cell Battery Model  Lifepo4/3.2v12.5AH
2 Nominal capacity   12.5Ah
 3 Nominal voltage 3.2V
 4  Internal Resistance (1KHZ AC )  6~8MΩ
5  Operating Voltage  2.5~3.65V
6  Standard Currents for Charing and Discharging 3.6A
 7  Max.Continuous Discharging current  12A
 8 max.Pluse Discharging Current (long pluse) 24A(3min)
 9  Max.Pluse Discharging Current(short pluse)36A(10S)
 10 Weight Approx 0.45kg
 11 48V100AH Battery pack Nominal voltage  51.2V
12 Nominal Energy(20±5℃0.3C@100%DOD)  5.12KWH
13 Battery System Configuration 8 parallel and 16 serial of single battery cells
 14  Battery System Operating Voltage Range 43.2V~56.8V
15 Floating Charging Voltage  53~54.4V
16 System Maximal Charging Current 20A
17 System  Maximal Discharging Current 80A~90A
18 48V2000AH Battery system  Nominal voltage 51.2V
19 Nominal Energy(20±5℃0.3C@100%DOD) 102.4KWH
20 Battery System Configuration  20 parallel  of 48V100AH packs
21 Battery System Operating Voltage Range43.2V~56.8V
22 Floating Charging Voltage53~54.4V
23System Maximal Charging Current400A
24 System Maximal Discharging Current 1600A~1800A
 25Application:*Single cells *48V100AH Battery Pack *48V2000AH Battery SystemOperating Temperature Range 0~45℃
26 Recommended Operating Range of SOC  10%~90%
27SOC Requirement for long period idle and storage30%SOC
28 Short term (1 month)Storage Temperature﹣20℃~45℃
29 Long  term (1 year)Storage Temperature ﹣20℃~25℃
30 Storage Humidity ﹤70%
31Operating Humidity ﹤80%
32 Insulation Resistance≥10MΩ
33 Communication to ExternalRS485
34Cycle life
≥2000years
35Battery warranty 5years
Note:1.It is required to install and operate the system in a indoor environment with temperature about 30~35℃
 2.The system must be charged with the specified  lithium Battery compactible charger